The materials used in the Equator system
are listed and accepted by WBS - Water Byelaws Scheme for use in
domestic installations in all the UKšs regional water authorities.
The PE-X pipe system offer excellent design flexibility with temperature
tolerances ranging from 120 ēC to - 20 ēC. The inherent composition
of plastic pipe makes the system very light in weight, roughly one
quarter that of equivalent copper pipework. Scale build up and noise
from water hammer are negligible with Equator pipe.
 |
Application |
Nominal
system flow temperature ēC |
Max
system service temperature ēC |
System
malfunction temperature ēC |
System
working pressure bar |
Cold
water system
|
20 |
20 |
- |
12 |
Vented
hot water systems
|
65 |
83 |
100 |
3.5 |
Unvented
hot water systems including instantaneous heaters and/or incorporating
storage (excludes discharge pipes from temperature and/or pressure
relief valves)
|
65 |
95 |
100 |
6.0 |
Vented
central heating systems
|
82 |
95 |
100 |
3.5 |
Sealed
central heating systems (excludes discharge pipes from temperature
and/or press
ure relief valves)
|
92 |
105 |
114 |
3.0 |
Underfloor
heating
|
60 |
83 |
100 |
3.5 |
Note
BS 5449 states that the central heating design flow temperature
shall not exceed 82 ēC. Pipe circuits prone to repeated high
level over heating such as found in gravity solid fuel and solar
heating systems are not suitable for Equator |
Table 1
Equator is classified in accordance with
BS7291 Part 3 Class S. The design life of Equator is at least 50
years when used for the applications and operating conditions listed
in Table 1. Equator may also be used in hot climates and for applications
such as grey water systems. For this type of application, where
the cold water will become warm, without the use of a heating appliance,
the maximum warm water operating limits are shown in Table 2 below.
 |
Operating
water temperature, °C
|
Maximum
pressure rating, bar |
30
|
11.5 |
40
|
11 |
50
|
10.5 |
|