Can
I use Equator for direct connection to the boiler?
|
| |
|
Yes, providing the heat exchanger is not cast iron and the connections
are outside the casing.
|
| |
 |
Can Equator fittings rotate? |
| |
|
Yes. All Equator push-fit fittings are free to rotate without compromising
seal integrity, even whilst subjected to water pressure.
|
| |
 |
Can I re-use the Equator fittings
once I have de-mounted it? |
| |
|
Yes, providing the O-ring has not been damaged. It is not possible
to replace the internal components of the Equator fitting.
|
| |
 |
Why shouldn¹t I use a hacksaw
to cut PE-X pipe? |
| |
|
Any lose PE-X particles could get lodged onto the O-ring and affect
the seal performance.
|
| |
 |
Will the PE-X material change
the taste of the water passing through it? |
| |
|
No.
|
| |
 |
Can any pipe support sleeve
be used with the Equator pipe? |
| |
|
Other brands of pipe support sleeves should not be used with Equator
pipe. The internal bore of other plastic pipe may differ from that
of Equator¹s. Equator support sleeves have been designed to suit
PE-X pipe in the Equator range, joint performance or damage to joint
components may occur if another brand of support sleeves are used
with Equator pipe.
|
| |
 |
Will Equator pipe be affected
if encased in floor screed? |
| |
|
No, Equator is not affected by cement and sand mortar. However,
to comply with Water Byelaws (UK) the pipe should be run using the
Equator conduit system.
|
| |
 |
How long after installation
will Equator last? |
| |
|
The test requirements of BS 7291 are designed to indicate life
expectancy of not less than 50 years.
|
| |
 |
Do you need to thermally insulate
Equator pipe and fittings from frost? |
| |
|
Yes, the same standard of lagging applicable to copper pipes should
be applied to plastic pipe and fittings.
|
| |
 |
Is Equator pipe and fittings
affected by soft water? |
| |
|
No, Marley's 30 years guarantee will remain applicable.
|
| |
 |
Can Equator pipe be used for
gas supply? |
| |
|
No.
|
| |
 |
Can Equator pipe be used for
externel pipes buried in the ground? |
| |
|
No, it is only classified for
use inside buildings. |